Perlick Refrigerators Error Codes

21 error codes extracted from Perlick refrigerators service manuals. Each code includes its meaning and a summary fix step.

Error Codes21 codes

UIX

Display Communication Fault

Reset power to unit, either using rocker switch or breaker. If fault continues: Call Service: +1 844-411-8050.

MEM

MC Memory Fault

Call Service: +1 844-411-8050.

TCX

Extra High Condenser Temperature

Call Service: +1 844-411-8050.

TEX

Evaporator temperature exceeds safe operation zone

Call Service: +1 844-411-8050.

TEY

Extra Low Evaporator Temperature

Run a manual defrost for unit. If the alarm repeats within a week: Call Service: +1 844-411-8050.

DO2

Door Opening Long Period

Close the door and activate a defrost cycle.

P1F

Zone 1 Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050.

P2F

Zone 2 Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050.

PEF

Evaporator Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050.

TCL

Low Condenser Temperature

Verify ambient temperature was above set point of the unit, if below set point see winterizing unit instructions.

PWR

Power Outage

Verify that all temperature sensitive product did not spoil during power loss.

PCF

Condenser Temperature Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050.

T1H

High Zone 1 Temperature

Verify door and gasket are fully sealing to fridge front. Check condenser coils for buildup and clean condenser coils pe...

T2H

High Zone 2 Temperature

Verify door and gasket are fully sealing to fridge front. If surrounding ambient temperature has recently changed dramat...

T1L

Low Zone 1 Temperature

Verify door and gasket are fully sealing to fridge front. If surrounding ambient temperature has recently changed dramat...

T2L

Low Zone 2 Temperature

Verify door and gasket are fully sealing to fridge front. If surrounding ambient temperature has recently changed dramat...

TCH

High Condenser Temperature

Clean condenser coils per maintenance instructions. If the alarm repeats within a week: Call Service: +1 844-411-8050.

TEL

Low Evaporator Temperature

Activate a defrost cycle. Verify the door shuts properly, gasket seals fully, and product is not blocking the evaporator...

DO1

Door Opening Short Period

Close the door.

PHF

Humidity Sensor Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050.

FCF

Condenser Fan Fault

Call Service: +1 844-411-8050.